Thank you for your interest in our available ECL1832 Transformer Power parts that is listed with the NSN 5950-00-107-6170. This particular ECL1832 NSN part has been manufactured by Bae Systems Information And Electronic Systems Integration Inc with the CAGE Code 80249. If you would like to purchase this particular NSN part, or any other available item on NSN World, feel free to fill out and submit an RFQ form as provided below. When you provide us information regarding your desired part number ECL1832, quantities, and target price, our team members can quickly formulate a quote that specifically caters to your individual needs and requirements as closely as possible. Additionally, team members are always available for customer needs 24/7x365, thus responses to quote requests will be furnished in as little as 15 minutes or less.
NSN World is a leader in part procurement, and we are your sourcing solution for Bae Systems Information And Electronic Systems Integration Inc parts like NSN 5950-00-107-6170 and other CAGE Code 80249 parts. National Stock Numbers, or NSNs, are 13-digit numeric codes that are used by NATO countries to identify and classify standardized material items of supply. With over 2 billion items in stock, NSN World is your part procurement solution for NSNs that have been sourced from top global manufacturers that we trust. Get started on the purchasing process today and see why customers steadily rely on NSN World for all their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-107-6170 Item Description: Transformer Power | 5950 | 001076170 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ecl1832 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
POWER | AARG | RELIABILITY INDICATORNOT ESTABLISHED |
POWER | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1 500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1 250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
POWER | ABTB | MOUNTING HOLE DIAMETER0 250 INCHES NOMINAL SINGLE GROUP |
POWER | ACZB | FREQUENCY RATING60 0 HERTZ NOMINAL SINGLE COMPONENT |
POWER | ACZC | INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
POWER | ACZU | ADJUSTMENT DEVICE DRIVE TYPESHAFT SINGLE COMPONENT |
POWER | ACZX | WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
POWER | ADAQ | BODY LENGTH2 000 INCHES NOMINAL |
POWER | ADAT | BODY WIDTH1 875 INCHES NOMINAL |
POWER | ADAU | BODY HEIGHT2 750 INCHES NOMINAL |
POWER | AKNA | INCLOSURE TYPEFULLY INCLOSED |
POWER | AKPV | MOUNTING FACILITY QUANTITY4 SINGLE GROUP |
POWER | AXGY | MOUNTING METHODFLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
POWER | BPLC | WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
POWER | CRBZ | WINDING OPERATING CURRENT4 0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
POWER | CTHD | ADJUSTMENT METHOD AND QUANTITY2 ADJUSTABLE CONTROL SINGLE COMPONENT |
POWER | CWJS | WINDING OPERATING VOLTAGE115 00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
POWER | TTQY | TERMINAL TYPE AND QUANTITY14 TAB SOLDER LUG |
"We proudly support the Intrepid Fallen Heroes Fund which aids United States Military personnel experiencing Invisible Wounds of War: Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). For additional information, please visit the website www.fallenheroesfund.org to help with their valiant efforts.” |