Thank you for your interest in our available 412D6782 Relay Electromagnetic parts that is listed with the NSN 5945-01-098-0528. This particular 412D6782 NSN part has been manufactured by Teledyne Reynolds Inc with the CAGE Code 11532. If you would like to purchase this particular NSN part, or any other available item on NSN World, feel free to fill out and submit an RFQ form as provided below. When you provide us information regarding your desired part number 412D6782, quantities, and target price, our team members can quickly formulate a quote that specifically caters to your individual needs and requirements as closely as possible. Additionally, team members are always available for customer needs 24/7x365, thus responses to quote requests will be furnished in as little as 15 minutes or less.
NSN World is a leader in part procurement, and we are your sourcing solution for Teledyne Reynolds Inc parts like NSN 5945-01-098-0528 and other CAGE Code 11532 parts. National Stock Numbers, or NSNs, are 13-digit numeric codes that are used by NATO countries to identify and classify standardized material items of supply. With over 2 billion items in stock, NSN World is your part procurement solution for NSNs that have been sourced from top global manufacturers that we trust. Get started on the purchasing process today and see why customers steadily rely on NSN World for all their operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-098-0528 Item Description: RELAY,ELECTROMAGNETIC | 5945 | 010980528 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
412D6782 | 3 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.280 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CBME | III CUBIC MEASURE | 0.030 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
FEAT | SPECIAL FEATURES | FAILURE RATE 3.0 |
TEST | TEST DATA DOCUMENT | 12436-6010157 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 9 PIN ALL FUNCTIONS |
"We proudly support the Intrepid Fallen Heroes Fund which aids United States Military personnel experiencing Invisible Wounds of War: Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). For additional information, please visit the website www.fallenheroesfund.org to help with their valiant efforts.” |